4CX250B PA regulated suppliesby John Stockley G8MNYIn the tetrode valve PAs like the 4CX250Bs a hard (stiff) grid & screen power rails are needed for optimum power & linearity. I found that a simple NPN emitter follower with a diode does a very good job both for the screen & grid supplies. GRID SUPPLY
The 100V 20mA NPN transistor, current amplifies the bias pot, so that peaks of grid current flows to ground through the NPN transistor & the 1K, the R dumps some of the power enabling the use of a small transiator. A diode from the pot to the grid (base-emitter) routes -ve volts through to the grid when there is no grid current. No sudden AC step change from the transistor to diode voltage is allowed due to the 100uF on the grid output. The DC must be fed to the grid via an RF choke (or low value wire wound R) & not via a high value resistor (other wise you wast all the effort of this design) if the peak drive grid current is going to drive the valve properly. Grid current meter of 10mA can be put in series with the grid PS note the polarity. N.B. on a 4CX250B a mean grid current of 2.5mA (0mA on a 4CX350!) is the recommended value for minimum 3rd order IP product. In class AB2 there could be half RF cycle peak current of about 50mA, which is needed to give a good half cycle RF peak anode current of greater than 1 Amp (350mA mean on meter over the whole cycle). Also recommended is the use of a RF power dump resistor across the grid tuned circuit to stop the onset of grid current current upsetting the drive rig SWR assuming you have more than 5W of drive. SCREEN SUPPLY
Again no sudden AC change from the transistor to diode step voltage is allowed due to the 1uF on the screen output. A normal mains 300V VDR is recommended on the valve base to dump any spikes from the anode 2KV supply that occasionally appear on the screen grid! (this is why neons are more reliable than Zeners) As the neons usually provide a -ve impedance characteristic series base resister RB of a few K ohms can make the O/P zero ohms. A simple DC load test can find the best value for RB. Screen Grid current meter of 25mA can be put in series with this PS, but should be protected with 2 1N4001 diodes. The PTT relay should connect the power to the valve to turn the valve
on for TX. Also note that the screen power should not be connected if the valve has not warmed up. (takes 1min), has no anode supply or has no bias supply. Again simple relay inhibit electronics can do all this. 73 De John, G8MNY @ GB7CIP
|
|
| |
|
| Home
| For
Sale & Wanted | Tell
a friend | Guestbook
| Cast Your Vote | Newsboard
| Amateur Radio
Forum | Links | Diary
Dates | | Games | SWLs | 'How To' Guides | Humour | Data Comms | Lottery | Amateur TV | Contests | Can You Help? | Contact Us | 10 Metres | | Clubs Worldwide | Subscribe to our Newsletter | | |
|
| |